Fire Panel System
HEX Fire
Panel System
Data Analysis & Cloud Storage
Provides real-time fire data analysis for firefighters to use in emergency rescue situations. This data can be stored on a cloud system which companies can access to analyze for further research.
Data Analysis & Cloud Storage
Provides real-time fire data analysis for firefighters to use in emergency rescue situations. This data can be stored on a cloud system which companies can access to analyze for further research.
Order Now
Responsive Fire Detection System
HEX's addressable smoke and temperature sensors are capable of detecting early stages of a fire; HEX's Fire Alarm and Evacuation System will then immediately notify the Dynamic Evacuation Signage Lights to begin routing the safest egress route.
Order Now
Provide latest status
For each device
Additional support through
Graphic display
Provide latest status
For each device
Additional support through
Graphic display
Guaranteed Fire Safety of All Buildings
Provide a total solution of whole building fire prevention and evacuation. Including plan and install the sensors and HEX Dynamic Evacuation Signage Lights in the sites.
Temp
Humidity
Density
Time
Carbon Monoxide Dangers
Carbon monoxide (CO) is a serious public health issue:
All people are at risk for CO poisoning. Breathing CO can cause headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion. If CO levels are high enough, people may lose consciousness or die.

Each year in the U.S., more than 400 people die from unintentional CO poisoning, more than 20,000 visit the emergency room, and more than 4,000 are hospitalized. According to Consumer Product Safety Commission reports that each carbon monoxide incident that requires medical attention costs about $16,000.

Carbon monoxide is a deadly, odorless, colorless, and poisonous gas. To avoid CO poisoning, installing a reliable carbon monoxide sensor can protect people’s lives. HEX CO sensors have been designed to alarm before potentially life-threatening levels of CO are reached, and issue the alarm to save your live.
back
System features
> Polarity with auxiliary power connection, information is
   transmitted as digital value through standard SLC
> Dedicated terminal capacitor
Tri-color indicator light
with reed switch(optional)
Stainless steel design
protects detector from dust and insect
Continuous detection for
separate eventsseparate events
System features
> With non-polar designed base, information is transmitted as
   digital value through standard SLC.
> Composite detector protects environment against
   different fire related elements.
Safe isolation
feature through fire control panel
Smoke, temperature, and differential heat detector
in one device
  • 6400 System Addressable
    Up to devices
  • 200 per circuit
    Addressable up to devices
  • 2000 past historical events
    Record up to
Dual monitors along with User-friendly interface allows building management staff to efficiently operate both fire alarm and dynamic evacuation systems.
Dual Monitor and User-friendly Panel
Order Now
LEARN MORE
System features
R-Type Fire Alarm Panel
> Double 17" Colored LCD Touchscreen
> Connect up to 32 Circuits
> System addressable up to 6400 devices
> Addressable up to 200 devices per circuit
> Records of detailed historical urgent events
> Record up to 2000 past historical events
> Provide latest status for each device
> Additional support through graphic display
   (optional)
back
Accessible and Flexible Protocol
HEX Fire Alarm and Evacuation System can be accessibly integrated with other systems and customized to meet the customer's security needs.
Contact Us
R-Type Fire Alarm Panel
Product
R-type Fire Alarm Panel
Circuit Board
Max DC 24V 25mA per Circuit
Model
Fl-8117
Emergency Signs
Max DC 24V 25mA Per Circuit
No. of address
Maximum 5120 Addresses
Annunciators
Fire, Smoke Damper, Smoke Extractor Fan, Sprinkler
System Annunciator, etc.
Construct
Wall-mount(92.5 x 50 x 19cm)
Call Equipment
Two Portable Phones
Main Power
AC110V/220V 60Hz 5A
Record
One Built-in Printer
Backup Power
Sealed Maintenance Free Lead-Acid Battery DC24V/10Ah
Operating Temperature
0°C ~ 40°C, Below 95% humidity
Circuit Voltage
DC24V±10%
Exterior Material
Steel 1.2mm painted
Power Usage
Fire Monitoring Current: 0.48A/
Alarm Current: 0.5A(AC110V)
Allowable Line Resistance
Max 10Ω per line
Display
17"LCD Screen x 2
EXPAND LIST
Addressable, multi-sensor detector
Detection of combination with visible smoke and rise of Temperature
Mutli
Smoke
Product Fire detector(addressable mutli-sensor)
Operating Voltage DC24V±10%
Standby Current 1mA
Alarm Current 2mA
Sensitivity 2.5% ~ 25%
Threshold Temperature 57°C
Operating Temperature 0°C ~ 50°C
Case Material PC Fire Proof Plastic
Indicator Dual LED Bulbs
Color White
Dimension 100 x 61 mm (D x H)
Input Circuit One Circuit
Transmit Method 2 wire Digital Signal serial transmission
Transmit Line Dimension 1.2mm ~ 1.6mm(HR)